− | Currently engagement concerning Pico PV Systems increases. In order to advance the framework for project development in this field EnDev has effected various activities. One of these is a test series for Pico PV Systems. It is divided into three phases:
| + | Pico PV Systems have emerged as a strong contender in the solar market of developing countries. Thus,[[Energising_Development_(EnDev)|EnDev]] has developed a test series to test their effectiveness.<br/> |
| | | |
− | <br> | + | == Technical Test I<br/> == |
| | | |
− | 1. Technical Test I
| + | The technical tests are performed by '''Fraunhofer Gesellschaft ([http://www.ise.fraunhofer.de/en?set_language=en FhG/ISE])''' in Freiburg, Germany. In the first test phase (2007/ 10 - 2008/ 01) twelve systems were tested on road capability with special focus on mechanical stability, lighting characteristics and operability. |
| | | |
− | 2. Technical Test II
| + | <u>These systems were in detail:</u> |
| | | |
− | 3. Field Tests<br>
| + | *GL9000SW, Global Marketing Technologies Inc. (US) --> overall picture bad |
| + | *MS01, Macro-Solar Technology Co,. Ltd (China) --> overall picture very bad |
| + | *Solar 2007-1, Solarprojekt-Freilassing e.v. (Germany) --> overall picture good |
| + | *Mightylight, Cosmos Ignite Innovations (India) --> overall picture good |
| + | *AISHWARYA, Noble energy Solar Technologies Ltd. (?) --> overall picture middle |
| + | *Solar Home System, "Afghanistan" --> overall picture very bad |
| + | *2212SL Wuara, SolEnergy Africa (PTY) Ltd (South Africa) --> overall picture very bad |
| + | *SOLUX-LED-100, SOLUX e.v. (Germany) --> overall picture middle |
| + | *Sun x-set mobile, Würth Solergy (Germany) --> overall picture middle - bad |
| + | *Glowstar GS7, Sollatek Ltd. (UK) --> overall picture middle |
| + | *AS018, Astral Solar technology Co. (China) --> overall picture bad |
| + | *SOLUX-LED-50, SOLUX e.v. (Germany) --> overall picture middle |
| | | |
− | === Technical Test I ===
| + | <br/> |
| | | |
− | The technical tests are performed by Fraunhofer Gesellschaft FhG/ISE in Freiburg, Germany. In the first test phase (2007/ 10 - 2008/ 01) twelve systems were tested on road capability with special focus on mechanical stability, lighting characteristics and operability. These systems were in detail:
| + | == Technical Test II<br/> == |
| | | |
− | *GL9000SW, Global Marketing Technologies Inc. (US) --> overall picture bad
| + | Seven solar lanterns reached the second testing stage, of which four are German-made: the Solux LED 100 and Solux LED 50 of the Solux e.V. development assistance project, the Solar 2007-1 by the Freilassing solar promotion project, and the sun x-set mobile produced by Würth. Other lamps of the main test were the Glowstar GS7 of the British company Sollatek, the Aishwarya NEST-6543 of the Indian manufacturer Noble Energy and the Mightylight 3040, also Indian made. |
− | *MS01, Macro-Solar Technology Co,. Ltd (China) --> overall picture very bad
| + | |
− | *Solar 2007-1, Solarprojekt-Freilassing e.v. (Germany) --> overall picture good
| + | |
− | *Mightylight, Cosmos Ignite Innovations (India) --> overall picture good
| + | |
− | *AISHWARYA, Noble energy Solar Technologies Ltd. (?) --> overall picture middle
| + | |
− | *Solar Home System, "Afghanistan" --> overall picture very bad
| + | |
− | *2212SL Wuara, SolEnergy Africa (PTY) Ltd (South Africa) --> overall picture very bad
| + | |
− | *SOLUX-LED-100, SOLUX e.v. (Germany) --> overall picture middle
| + | |
− | *Sun x-set mobile, Würth Solergy (Germany) --> overall picture middle - bad
| + | |
− | *Glowstar GS7, Sollatek Ltd. (UK) --> overall picture middle
| + | |
− | *AS018, Astral Solar technology Co. (China) --> overall picture bad
| + | |
− | *SOLUX-LED-50, SOLUX e.v. (Germany) --> overall picture middle <br>
| + | |
| | | |
− | <br> | + | <u>In the following table you find a selection of the most important criteria:</u> |
| | | |
− | Detailed test description can be inspected here:<br>Technical Test I (in german)<br>
| + | '''Testcriteria Level 2''' |
| | | |
− | === Technical Test II ===
| + | {| cellspacing="0" cellpadding="3" border="1" style="width: 70%; width: 100%" |
− | | + | |
− | Seven solar lanterns reached the second testing stage, of which four are German-made: the Solux LED 100 and Solux LED 50 of the Solux e.V. development assistance project, the Solar 2007-1 by the Freilassing solar promotion project, and the sun x-set mobile produced by Würth. Other lamps of the main test were the Glowstar GS7 of the British company Sollatek, the Aishwarya NEST-6543 of the Indian manufacturer Noble Energy and the Mightylight 3040, also Indian made. <br>
| + | |
− | | + | |
− | In the following table you find a selection of the most important criteria:<br>
| + | |
− | | + | |
− | <br>
| + | |
− | | + | |
− | Testcriteria Level 2
| + | |
− | | + | |
− | {| width="70%" cellspacing="0" cellpadding="3" border="1" | + | |
| |- | | |- |
| | | | | |
− | Solar module | + | Solar module |
| | | |
| | | | | |
− | Does the system deliver the nominal rated values of power output, open- circuit voltage and shortcircuit current? <br> | + | Does the system deliver the nominal rated values of power output, open- circuit voltage and shortcircuit current? |
| | | |
| |- | | |- |
− | | <div class="draft"></div> Battery | + | | <div class="draft"></div>Battery<br/> |
| | | | | |
− | Measure of capacity (NiMH+ Pb), persistence against overcharging (NiMH), simple durability test (NiMH)<span style="font-size: 11pt; font-family: arial;"> | + | Measure of capacity (NiMH+ Pb), persistence against overcharging (NiMH), simple durability test (NiMH)<span style="font-size: 11pt; font-family: arial"></span> |
− | </span> | + | |
| | | |
| |- | | |- |
| | | | | |
− | Luminous fux<span style="font-size: 11pt; font-family: arial;"> | + | Luminous fux<span style="font-size: 11pt; font-family: arial"></span> |
− | </span> | + | |
| | | |
| | | | | |
− | average of 210 minutes | + | average of 210 minutes |
| | | |
| |- | | |- |
| | | | | |
− | Brennzeit/autonome Zeit <br> | + | Brennzeit/autonome Zeit |
| | | |
| | | | | |
− | The duration is measured until luminous flux falls to 70 % of the initial value. (beginning from a fully-charged battery) <br> | + | The duration is measured until luminous flux falls to 70 % of the initial value. (beginning from a fully-charged battery) |
| | | |
| |- | | |- |
− | | Luminous efficacy<br> | + | | Luminous efficacy<br/> |
| | | | | |
− | average is obtained from a period of 210 minutes, beginning from a fully-charged battery.<br> | + | average is obtained from a period of 210 minutes, beginning from a fully-charged battery. |
| | | |
| |- | | |- |
− | | Charge Controller<br> | + | | Charge Controller<br/> |
| | | | | |
− | Spannungslevel Ladeschluss-/ Lastabwurfspannung, Eigenverbrauch, Signalisierungen, Schutz vor Entladung durch Modul, Wirkungsgrad <br> | + | Spannungslevel Ladeschluss-/ Lastabwurfspannung, Eigenverbrauch, Signalisierungen, Schutz vor Entladung durch Modul, Wirkungsgrad |
| | | |
| |- | | |- |
− | | Ballast device<br> | + | | Ballast device<br/> |
| | | | | |
− | How good is the efficiency of the ballast?<br> | + | How good is the efficiency of the ballast? |
| | | |
| |- | | |- |
| | | | | |
− | Cycle test / degradation of CFL-lamps<br> | + | Cycle test / degradation of CFL-lamps |
| | | |
| | | | | |
− | How long do CFL lamps last when subjected to a switching cycle of ‘on’ for 60 seconds, ‘off’ for 150 seconds? <br> | + | How long do CFL lamps last when subjected to a switching cycle of ‘on’ for 60 seconds, ‘off’ for 150 seconds? |
| | | |
| |- | | |- |
| | | | | |
− | Simulation <br> | + | Simulation |
| | | |
| | | | | |
− | Ermittlung der solaren Deckungsrate für 5 Standorte bei einer Brenndauer von täglich 3,5 Stunden <br> | + | Ermittlung der solaren Deckungsrate für 5 Standorte bei einer Brenndauer von täglich 3,5 Stunden |
| | | |
| |} | | |} |
| | | |
− | <br> | + | <br/> |
| + | |
| + | == Field Test<br/> == |
| + | |
| + | <u><span class="MsoPageNumber"><span style="font-size: 10pt; font-family: 'arial','sans-serif'">The publication is available in English and German:</span></span></u> |
| + | |
| + | *[[:File:Solar Lanterns Test - Shades of Light.pdf|English version]] |
| + | *[[:File:Solarleuchtentest - Licht und Schatten.pdf|German version]]<span class="MsoPageNumber"><span style="font-size: 10pt; font-family: 'arial','sans-serif'"></span></span> |
| | | |
− | === Field Test ===
| + | <br/> |
| | | |
− | <span class="MsoPageNumber"><span style="font-size: 10pt; font-family: 'arial','sans-serif';">The publication is available in English and German.</span></span>
| |
| | | |
− | *[http://energypedia.info/img_auth.php/e/ed/Gtz_solar_lanterns_test.pdf <span class="MsoPageNumber"><span style="font-size: 10pt; font-family: 'arial','sans-serif';">English version</span></span>]
| + | = Further Information = |
− | *[[:file:Gtz solarleuchtentest.pdf|<span class="MsoPageNumber"><span style="font-size: 10pt; font-family: 'arial','sans-serif';">German version</span></span>]]<span class="MsoPageNumber"><span style="font-size: 10pt; font-family: 'arial','sans-serif';"> </span></span>
| + | |
| | | |
− | ==== Additional Info ====
| + | *[[PicoPV Field Tests|PicoPV Field Tests (of GTZ EnDev)]] |
| + | *The SOLAR 2007-1 Lantern (Solarprojekt Freilassing e.V.)has been upgraded with new LEDs of 80 lm/W. |
| | | |
− | The SOLAR 2007-1 Lantern (Solarprojekt Freilassing e.V.)has been upgraded with new LEDs of 80 lm/W.
| + | <br/> |
| | | |
− | [[Category:PicoPV]] [[Category:Solar]] | + | [[Category:PicoPV]] |
| + | [[Category:Solar]] |
Pico PV Systems have emerged as a strong contender in the solar market of developing countries. Thus,EnDev has developed a test series to test their effectiveness.
Seven solar lanterns reached the second testing stage, of which four are German-made: the Solux LED 100 and Solux LED 50 of the Solux e.V. development assistance project, the Solar 2007-1 by the Freilassing solar promotion project, and the sun x-set mobile produced by Würth. Other lamps of the main test were the Glowstar GS7 of the British company Sollatek, the Aishwarya NEST-6543 of the Indian manufacturer Noble Energy and the Mightylight 3040, also Indian made.