Line 10: |
Line 10: |
| === Stall === | | === Stall === |
| | | |
− | [[Image:Wind turbine blade aerodynamics - stall control.jpg|frame|center|Wind turbine blade aerodynamics - stall control]]<ref>Weigel S., Poeller M. (2010) Wind Turbine Generators (WTGs) Physical Principals and Generator Concepts, Presentation prepared by DigSILENT GmbH for the Wind Energy and Development Dialogue 2010, retrieved 27.8.2011 [[http://www.gtz.de/de/dokumente/gtz2010-en-wedd-1-2-WTG-concepts.pdf]]</ref> | + | [[Image:Wind turbine blade aerodynamics - stall control.jpg|frame|center|Wind turbine blade aerodynamics - stall control]]<ref>Weigel S., Poeller M. (2010) Wind Turbine Generators (WTGs) Physical Principals and Generator Concepts, Presentation prepared by DigSILENT GmbH for the Wind Energy and Development Dialogue 2010, retrieved 27.8.2011 [[http://www.gtz.de/de/dokumente/gtz2010-en-wedd-1-2-WTG-concepts.pdf]]</ref> |
| | | |
− | Stall Control:<br>– Passive Stall:<br>Power of the wind turbine is limited by the aerodynamic characteristics<br>of the turbine.<br>– Active stall:<br>Power of the wind turbine is limited additionally by decreasing the pitch<br>angle (increasing the inflow angle ).<br> | + | Stall Control:<br>– Passive Stall:<br>Power of the wind turbine is limited by the aerodynamic characteristics<br>of the turbine.<br>– Active stall:<br>Power of the wind turbine is limited additionally by decreasing the pitch<br>angle (increasing the inflow angle ).<br> |
| | | |
| === Pitch<br> === | | === Pitch<br> === |
| | | |
− | [[Image:Wind turbine blade aerodynamics - pitching.jpg|frame|center|Aerodynamics at a wind turbine blade during control through pitching]]<ref>Weigel S., Poeller M. (2010) Wind Turbine Generators (WTGs) Physical Principals and Generator Concepts, Presentation prepared by DigSILENT GmbH for the Wind Energy and Development Dialogue 2010, retrieved 27.8.2011 [[http://www.gtz.de/de/dokumente/gtz2010-en-wedd-1-2-WTG-concepts.pdf]]</ref> | + | [[Image:Wind turbine blade aerodynamics - pitching.jpg|frame|center|Aerodynamics at a wind turbine blade during control through pitching]]<ref>Weigel S., Poeller M. (2010) Wind Turbine Generators (WTGs) Physical Principals and Generator Concepts, Presentation prepared by DigSILENT GmbH for the Wind Energy and Development Dialogue 2010, retrieved 27.8.2011 [[http://www.gtz.de/de/dokumente/gtz2010-en-wedd-1-2-WTG-concepts.pdf]]</ref> |
| | | |
| Pitch Control:<br>– Power of the wind turbine is limited by increasing the pitch angle<br>(decreasing the inflow angle <math>\alpha</math>)<br> | | Pitch Control:<br>– Power of the wind turbine is limited by increasing the pitch angle<br>(decreasing the inflow angle <math>\alpha</math>)<br> |
Line 60: |
Line 60: |
| === Fixed Speed Induction Generator<br> === | | === Fixed Speed Induction Generator<br> === |
| | | |
− | [[Image:Fixed speed induction generator.jpg|frame|center|Fixed speed induction generator.jpg]]<ref>Weigel S., Poeller M. (2010) Wind Turbine Generators (WTGs) Physical Principals and Generator Concepts, Presentation prepared by DigSILENT GmbH for the Wind Energy and Development Dialogue 2010, retrieved 27.8.2011 [[http://www.gtz.de/de/dokumente/gtz2010-en-wedd-1-2-WTG-concepts.pdf]]</ref> | + | [[Image:Fixed speed induction generator.jpg|frame|center|Fixed speed induction generator.jpg]]<ref>Weigel S., Poeller M. (2010) Wind Turbine Generators (WTGs) Physical Principals and Generator Concepts, Presentation prepared by DigSILENT GmbH for the Wind Energy and Development Dialogue 2010, retrieved 27.8.2011 [[http://www.gtz.de/de/dokumente/gtz2010-en-wedd-1-2-WTG-concepts.pdf]]</ref> |
| | | |
| Only fix speed operation possible (stall control required)<br>• Reactive power compensation required<br>• No reactive power control capability. Additional devices required:<br>– TSCs (Thyristor switched capacitors)<br>– STATCOMs<br>• Risk of dynamic voltage collapse<br>GTZ Expert Workshop 2010: Grid and System Integration of Wind Energy, 22/23.11.2010, Berlin/Germany<br>y g p<br>– > Typically, wind generators based on induction generators are asked to<br>disconnect in case of voltage dips<br> | | Only fix speed operation possible (stall control required)<br>• Reactive power compensation required<br>• No reactive power control capability. Additional devices required:<br>– TSCs (Thyristor switched capacitors)<br>– STATCOMs<br>• Risk of dynamic voltage collapse<br>GTZ Expert Workshop 2010: Grid and System Integration of Wind Energy, 22/23.11.2010, Berlin/Germany<br>y g p<br>– > Typically, wind generators based on induction generators are asked to<br>disconnect in case of voltage dips<br> |
Line 66: |
Line 66: |
| === Induction Generator with Variable Rotor Resistance<br> === | | === Induction Generator with Variable Rotor Resistance<br> === |
| | | |
− | [[Image:Induction Generator with Variable Rotor Resistance.jpg|frame|center|Induction Generator with Variable Rotor Resistance.jpg]]<ref>Weigel S., Poeller M. (2010) Wind Turbine Generators (WTGs) Physical Principals and Generator Concepts, Presentation prepared by DigSILENT GmbH for the Wind Energy and Development Dialogue 2010, retrieved 27.8.2011 [[http://www.gtz.de/de/dokumente/gtz2010-en-wedd-1-2-WTG-concepts.pdf]]</ref> | + | [[Image:Induction Generator with Variable Rotor Resistance.jpg|frame|center|Induction Generator with Variable Rotor Resistance.jpg]]<ref>Weigel S., Poeller M. (2010) Wind Turbine Generators (WTGs) Physical Principals and Generator Concepts, Presentation prepared by DigSILENT GmbH for the Wind Energy and Development Dialogue 2010, retrieved 27.8.2011 [[http://www.gtz.de/de/dokumente/gtz2010-en-wedd-1-2-WTG-concepts.pdf]]</ref> |
| | | |
| Simple concept for variable speed operation.<br>• Reactive power compensation required.<br>• No reactive power control capability. Additional devices required:<br>– TSCs (Thyristor switched capacitors)<br>– STATCOMs<br>• Limited LVRT capability. Dynamic voltage collapse problems have to<br>GTZ Expert Workshop 2010: Grid and System Integration of Wind Energy, 22/23.11.2010, Berlin/Germany<br>be mitigated by:<br>– Fast increase of rotor resistance during faults<br>– Additional reactive power compensation devices (typically TSCs)<br> | | Simple concept for variable speed operation.<br>• Reactive power compensation required.<br>• No reactive power control capability. Additional devices required:<br>– TSCs (Thyristor switched capacitors)<br>– STATCOMs<br>• Limited LVRT capability. Dynamic voltage collapse problems have to<br>GTZ Expert Workshop 2010: Grid and System Integration of Wind Energy, 22/23.11.2010, Berlin/Germany<br>be mitigated by:<br>– Fast increase of rotor resistance during faults<br>– Additional reactive power compensation devices (typically TSCs)<br> |
Line 86: |
Line 86: |
| === Directly Coupled Synchronous Generator with Variable Gear Box<br> === | | === Directly Coupled Synchronous Generator with Variable Gear Box<br> === |
| | | |
− | [[Image:Directly Coupled Synchronous Generator with Variable Gear Box.jpg|frame|center|Directly Coupled Synchronous Generator with Variable Gear Box.jpg]]<ref>Weigel S., Poeller M. (2010) Wind Turbine Generators (WTGs) Physical Principals and Generator Concepts, Presentation prepared by DigSILENT GmbH for the Wind Energy and Development Dialogue 2010, retrieved 27.8.2011 [[http://www.gtz.de/de/dokumente/gtz2010-en-wedd-1-2-WTG-concepts.pdf]]</ref> | + | [[Image:Directly Coupled Synchronous Generator with Variable Gear Box.jpg|frame|center|Directly Coupled Synchronous Generator with Variable Gear Box.jpg]]<ref>Weigel S., Poeller M. (2010) Wind Turbine Generators (WTGs) Physical Principals and Generator Concepts, Presentation prepared by DigSILENT GmbH for the Wind Energy and Development Dialogue 2010, retrieved 27.8.2011 [[http://www.gtz.de/de/dokumente/gtz2010-en-wedd-1-2-WTG-concepts.pdf]]</ref> |
| + | |
| + | == References == |
| + | |
| + | <references /> |
| | | |
| [[Portal:Wind]] | | [[Portal:Wind]] |
| | | |
| [[Category:Wind]] | | [[Category:Wind]] |
Simple concept for variable speed operation.
• Reactive power compensation required.
• No reactive power control capability. Additional devices required:
– TSCs (Thyristor switched capacitors)
– STATCOMs
• Limited LVRT capability. Dynamic voltage collapse problems have to
GTZ Expert Workshop 2010: Grid and System Integration of Wind Energy, 22/23.11.2010, Berlin/Germany
be mitigated by:
– Fast increase of rotor resistance during faults
– Additional reactive power compensation devices (typically TSCs)