Line 26: |
Line 26: |
| {| class="FCK__ShowTableBorders" cellspacing="1" cellpadding="1" width="100%" border="0" | | {| class="FCK__ShowTableBorders" cellspacing="1" cellpadding="1" width="100%" border="0" |
| |- | | |- |
− | | [[File:Haeusleberg farm.jpg|370px|A view over the Häusleberg organic farm]]<br/> | + | | colspan="2" | |
| + | [[File:Haeusleberg farm.jpg|760px|A view over the Häusleberg organic farm]] |
| + | |
| + | |- |
| + | | colspan="2" | |
| + | A view over the Häusleberg organic farm.<br/> |
| + | |
| + | |- |
| | [[File:Haeusleberg turbine 1.jpg|370px|Side view of the installed turbine]]<br/> | | | [[File:Haeusleberg turbine 1.jpg|370px|Side view of the installed turbine]]<br/> |
| + | | [[File:Haeusleberg turbine 2.jpg|370px|Top view of the installed turbine]]<br/> |
| |- | | |- |
− | | A view over the Häusleberg organic farm.
| |
| | Side view of the installed turbine atop the wooden framed drainage barrel. | | | Side view of the installed turbine atop the wooden framed drainage barrel. |
| + | | Top view of the installed turbine atop the wooden framed drainage barrel.<br/> |
| |- | | |- |
− | | [[File:Haeusleberg turbine 2.jpg|370px|Top view of the installed turbine]]<br/>
| |
| | [[File:Haeusleberg turbine 3.jpg|370px|The turbine from below]]<br/> | | | [[File:Haeusleberg turbine 3.jpg|370px|The turbine from below]]<br/> |
| + | | [[File:Haeusleberg turbine 4.jpg|370px|The stator]]<br/> |
| |- | | |- |
− | | Top view of the installed turbine atop the wooden framed drainage barrel.
| + | | The turbine from below showing the pelton runner at the nozzle mounting bracket.<br/> |
− | | The turbine from below showing the pelton runner at the nozzle mounting bracket. | + | | The stator of the direct drive motor during modifications for the 12 V hybrid system.<br/> |
| |- | | |- |
− | | [[File:Haeusleberg turbine 4.jpg|370px|The stator]]<br/>
| |
| | [[File:Haeusleberg turbine 5.jpg|370px|Nozzle alignment test]]<br/> | | | [[File:Haeusleberg turbine 5.jpg|370px|Nozzle alignment test]]<br/> |
| + | | |
| |- | | |- |
− | | The stator of the direct drive motor during modifications for the 12 V hybrid system.
| |
| | Nozzle alignment test. | | | Nozzle alignment test. |
| + | | |
| |} | | |} |
| | | |
| [[Category:Germany]] | | [[Category:Germany]] |
| [[Category:Micro_Hydro]] | | [[Category:Micro_Hydro]] |
Revision as of 22:16, 11 December 2012
Location of the site:
- Country: Germany
- District: Baden-Württemberg
- River: Schanzbach
- GPS Coordinates: 47º55’40.5’’N 7º55’31.2’’E
This small pelton turbine is part of a hybrid system which supplies electricity to the Häusleberg Organic Farm. For more information please go to the project website:
https://sites.google.com/site/haeusleberg/
Start of construction: December 2011
Date of Commissioning: June 2012
Ownership / Operation Model: Privately owned
Tariff structure: Not applicable
Turbine: Pelton
Generator: Modified direct drive motor, 3 phase, 20 V, 150 W (approximately)
Error creating thumbnail: convert: unable to open image `/var/www/ISWiki/prod/current/energypedia/images/8/87/Haeusleberg_farm.jpg': No such file or directory @ error/blob.c/OpenBlob/2641. convert: no images defined `/tmp/transform_22c5e2a-1.jpg' @ error/convert.c/ConvertImageCommand/3044.
|
A view over the Häusleberg organic farm.
|
Error creating thumbnail: convert: unable to open image `/var/www/ISWiki/prod/current/energypedia/images/3/3a/Haeusleberg_turbine_1.jpg': No such file or directory @ error/blob.c/OpenBlob/2641. convert: no images defined `/tmp/transform_5414006-1.jpg' @ error/convert.c/ConvertImageCommand/3044.
|
Error creating thumbnail: convert: unable to open image `/var/www/ISWiki/prod/current/energypedia/images/4/49/Haeusleberg_turbine_2.jpg': No such file or directory @ error/blob.c/OpenBlob/2641. convert: no images defined `/tmp/transform_5be4e27-1.jpg' @ error/convert.c/ConvertImageCommand/3044.
|
Side view of the installed turbine atop the wooden framed drainage barrel.
|
Top view of the installed turbine atop the wooden framed drainage barrel.
|
Error creating thumbnail: convert: unable to open image `/var/www/ISWiki/prod/current/energypedia/images/a/a0/Haeusleberg_turbine_3.jpg': No such file or directory @ error/blob.c/OpenBlob/2641. convert: no images defined `/tmp/transform_410ac66-1.jpg' @ error/convert.c/ConvertImageCommand/3044.
|
Error creating thumbnail: convert: unable to open image `/var/www/ISWiki/prod/current/energypedia/images/9/97/Haeusleberg_turbine_4.jpg': No such file or directory @ error/blob.c/OpenBlob/2641. convert: no images defined `/tmp/transform_ce5989-1.jpg' @ error/convert.c/ConvertImageCommand/3044.
|
The turbine from below showing the pelton runner at the nozzle mounting bracket.
|
The stator of the direct drive motor during modifications for the 12 V hybrid system.
|
Error creating thumbnail: convert: unable to open image `/var/www/ISWiki/prod/current/energypedia/images/4/41/Haeusleberg_turbine_5.jpg': No such file or directory @ error/blob.c/OpenBlob/2641. convert: no images defined `/tmp/transform_4ab8d84-1.jpg' @ error/convert.c/ConvertImageCommand/3044.
|
|
Nozzle alignment test.
|
|