(31 intermediate revisions by 2 users not shown) |
Line 2: |
Line 2: |
| = Overview<br/> = | | = Overview<br/> = |
| | | |
− | Name of the site: El Plan<br/> | + | {| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;" |
− | Country: Nicaragua (GPS Coordinates: ?)<br/>
| + | |- |
− | Turbine Type: Pelton<br/> | + | | style="width: 194px;" | <span style="line-height: 18px;">Name of the site:</span> |
− | Power Output: XkW <br/> | + | | style="width: 390px;" | El Plan |
− | Start of Construction: December 2011<br/>
| + | |- |
− | Date of Commissioning: June 2012<br/>
| + | | style="width: 194px;" | <span style="line-height: 18px;">Country:</span> |
− | Comments: <br/> | + | | style="width: 390px;" | <span style="line-height: 18px;">[[Nicaragua_Energy_Situation|Nicaragua]] (GPS Coordinates: 637682/1389321)</span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Turbine Type:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;">Pelton</span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Power Output:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;">24 kW (5.7kW)</span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Project Status:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;">in operation</span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Comments:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;">-</span> |
| + | |} |
| | | |
− | = Operation Data<br/> =
| + | <br/> |
− | | + | |
− | Head: <br/>
| + | |
− | Flow: <br/>
| + | |
| | | |
| + | <br/> |
| | | |
| + | <br/> |
| | | |
| + | = Operation Data<br/> = |
| | | |
| + | {| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;" |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Gross Head:</span> |
| + | | style="width: 390px;" | 200m<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Net/Design Head:</span> |
| + | | style="width: 390px;" | 200m<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Flow (design flow):</span> |
| + | | style="width: 390px;" | 20 l/s<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 290px;" | <span style="line-height: 18px;">Comments on flow variation during the year:</span> |
| + | | style="width: 294px;" | Problems with flow during dry season.<span style="line-height: 18px;"></span> |
| + | |} |
| | | |
| + | <br/> |
| | | |
| + | <br/> |
| | | |
| + | <br/> |
| | | |
| = Technical Information<br/> = | | = Technical Information<br/> = |
| | | |
| + | {| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;" |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Comments:</span> |
| + | | style="width: 390px;" | - |
| + | |} |
| | | |
| + | <br/> |
| | | |
| + | == Civil Works and Penstock<br/> == |
| | | |
− | == Civil Works<br/> == | + | {| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;" |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Dam construction material:</span> |
| + | | style="width: 390px;" | Concrete<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Dam Dimensions:</span> |
| + | | style="width: 390px;" | -<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Storage Volume Reservoir:</span> |
| + | | style="width: 390px;" | d=11m x 2m height |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Sedimentation Basin material:</span> |
| + | | style="width: 390px;" | Concrete <span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Sedimentation Basin Dimensions:</span> |
| + | | style="width: 390px;" | -<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Penstock Length:</span> |
| + | | style="width: 390px;" | 1200m<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Penstock Diameter at Beginning:</span> |
| + | | style="width: 390px;" | 6" |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Penstock Diameter at End:</span> |
| + | | style="width: 390px;" | 3" |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Penstock Changes of Diameter:</span> |
| + | | style="width: 390px;" | 1<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Penstock Material:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;">PVC</span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Security Valve:</span> |
| + | | style="width: 390px;" | yes, 3"<span style="line-height: 18px;"></span> |
| + | |} |
| | | |
| == Electromechanical Equipment<br/> == | | == Electromechanical Equipment<br/> == |
| | | |
− | Turbine: | + | === Turbine === |
| | | |
| + | {| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;" |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Turbine Type:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;">Pelton, 1 injector</span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Turbine Diameter:</span> |
| + | | style="width: 390px;" | - |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Turbine Material:</span> |
| + | | style="width: 390px;" | Bronce |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Turbine Manufacturer:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;">Nica Bosch (Contact: company does not exist any more)</span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Potencial (nominal):</span> |
| + | | style="width: 390px;" | 24 kW<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Rated Head:</span> |
| + | | style="width: 390px;" | 200m<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Rated Flow:</span> |
| + | | style="width: 390px;" | 20 l/s<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Rated Speed:</span> |
| + | | style="width: 390px;" | 1800 rpm |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Runaway Speed:</span> |
| + | | style="width: 390px;" | -<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Shaft diameter and material:</span> |
| + | | style="width: 390px;" | 38mm<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Direction of Rotation:</span> |
| + | | style="width: 390px;" | clockwise<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Orientation of Shaft:</span> |
| + | | style="width: 390px;" | horizontal<span style="line-height: 18px;"></span> |
| + | |} |
| | | |
− | Generator: | + | === Generator: === |
| | | |
| + | {| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;" |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Generator Manufacturer and Model:</span> |
| + | | style="width: 390px;" | OGI, LLC<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Phases:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;">3</span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Potencial (nominal):</span> |
| + | | style="width: 390px;" | 18kW<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Nominal voltage:</span> |
| + | | style="width: 390px;" | 240 / 120V<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Nominal Speed:</span> |
| + | | style="width: 390px;" | 1800 rpm<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Frequency:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;">60 Hz</span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Isolation Class:</span> |
| + | | style="width: 390px;" | H<span style="line-height: 18px;"></span> |
| + | |} |
| + | |
| + | === Mechanical Transmission / Coupling === |
| + | |
| + | {| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;" |
| + | |- |
| + | | style="width: 190px;" | <span style="line-height: 18px;">Type of Coupling:</span> |
| + | | style="width: 394px;" | Direct Coupling<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 190px;" | <br/> |
| + | | style="width: 394px;" | <br/> |
| + | |} |
| + | |
| + | === Control System === |
| + | |
| + | {| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;" |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Control System Manufacturer and Model:</span> |
| + | | style="width: 390px;" | Thomson and Howe Energy Systems, J2<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Type of Control:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;">Load Control</span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Capacity:</span> |
| + | | style="width: 390px;" | 12kW<span style="line-height: 18px;"></span> |
| + | |} |
| + | |
| + | <br/> |
| | | |
| == Electrical Transmission<br/> == | | == Electrical Transmission<br/> == |
| + | |
| + | {| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;" |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Mini Grid:</span> |
| + | | style="width: 390px;" | yes<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Connection to national Grid:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;">no</span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Grid Voltage:</span> |
| + | | style="width: 390px;" | 240 / 120 V<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Diameter of Conductor:</span> |
| + | | style="width: 390px;" | Triplex 2ASCR |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Transformer Rating:</span> |
| + | | style="width: 390px;" | not available<span style="line-height: 18px;"></span> |
| + | |} |
| + | |
| + | <br/> |
| | | |
| = Economic Information<br/> = | | = Economic Information<br/> = |
| | | |
− | Developer: (Contact: )<br/> | + | {| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;" |
− | Operator: (Contact: )<br/>
| + | |- |
− | Ownership / Operation Model: Privately owned<br/> | + | | style="width: 194px;" | <span style="line-height: 18px;">Developer: (Contact: )</span> |
− | Tariff structure: Not applicable<br/> | + | | style="width: 390px;" | <span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Start of Construction:</span> |
| + | | style="width: 390px;" | <br/> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Date of Commissioning:</span> |
| + | | style="width: 390px;" | <br/> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Ownership / Operation Model:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Operator:</span> |
| + | | style="width: 390px;" | <br/> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Tariff structure:</span> |
| + | | style="width: 390px;" | 50 Cordobas |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Connected Housholds:</span> |
| + | | style="width: 390px;" | 22<span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Connection Cost Cost to be covered by houshold:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;"></span> |
| + | |- |
| + | | style="width: 194px;" | <span style="line-height: 18px;">Overall Project Costs:</span> |
| + | | style="width: 390px;" | <span style="line-height: 18px;"></span> |
| + | |} |
| + | |
| + | <br/> |
| + | |
| + | <br/> |
| + | |
| + | <br/> |
| + | |
| + | <br/> |
| | | |
| = Project Photos<br/> = | | = Project Photos<br/> = |
| + | |
| + | {| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 800px;" |
| + | |- |
| + | | [[File:ElPlan.JPG|thumb|right|300px|alt=ElPlan.JPG]]<br/><br/> |
| + | | [[File:Valve.JPG|thumb|right|300px|alt=Valve.JPG]] |
| + | |- |
| + | | [[File:Control System El Plan.JPG|thumb|right|300px|alt=Control System El Plan.JPG]] |
| + | | [[File:Penstock El Plan.JPG|thumb|right|300px|alt=Penstock El Plan.JPG]] |
| + | |- |
| + | | [[File:Turbine El Plan.JPG|thumb|right|300px|alt=Turbine El Plan.JPG]] |
| + | | [[File:Runner 2 El PLan.JPG|thumb|right|300px|alt=Runner 2 El PLan.JPG]] |
| + | |- |
| + | | [[File:Dam el Plan.JPG|thumb|right|300px|alt=Dam el Plan.JPG]] |
| + | | |
| + | |} |
| + | |
| + | <br/><br/> |
| + | |
| + | [[Category:Micro_Hydro]] |