(4 intermediate revisions by one user not shown) |
Line 1: |
Line 1: |
| + | |
| = Overview<br/> = | | = Overview<br/> = |
| | | |
| '''<u>Location of the site:</u>''' | | '''<u>Location of the site:</u>''' |
− | | + | *<u>Country</u>: [[Germany_Energy_Situation|Germany]] |
− | *<u>Country</u>: Germany | + | *<u>District</u>: <span style="color: rgb(34, 34, 34); font-family: arial, sans-serif; font-size: small; line-height: 16px">Baden-Württemberg</span> |
− | *<u>District</u>: <span style="color: rgb(34, 34, 34); font-family: arial, sans-serif; font-size: small; line-height: 16px">Baden-Württemberg</span> | + | |
| *<u>River</u>: Schanzbach | | *<u>River</u>: Schanzbach |
| *<u>GPS Coordinates</u>: 47<span style="text-align: left">º55’40.5’’N 7º55’31.2’’E</span> | | *<u>GPS Coordinates</u>: 47<span style="text-align: left">º55’40.5’’N 7º55’31.2’’E</span> |
| | | |
| <br/>This pico pelton turbine is part of a hybrid system which supplies electricity to the Häusleberg Organic Farm. For more information please go to the project website: [https://sites.google.com/site/haeusleberg/ sites.google.com/site/haeusleberg/] | | <br/>This pico pelton turbine is part of a hybrid system which supplies electricity to the Häusleberg Organic Farm. For more information please go to the project website: [https://sites.google.com/site/haeusleberg/ sites.google.com/site/haeusleberg/] |
− |
| |
| | | |
| | | |
Latest revision as of 12:22, 17 July 2014
[edit] Overview
Location of the site:
- Country: Germany
- District: Baden-Württemberg
- River: Schanzbach
- GPS Coordinates: 47º55’40.5’’N 7º55’31.2’’E
This pico pelton turbine is part of a hybrid system which supplies electricity to the Häusleberg Organic Farm. For more information please go to the project website: sites.google.com/site/haeusleberg/
[edit] Further Information - Project
Start of Construction: December 2011
Date of Commissioning: June 2012
Ownership / Operation Model: Privately owned
Tariff structure: Not applicable
Turbine: Pelton
Generator: Modified direct drive motor, 3 phase, 20 V, 150 W (approximately)
Error creating thumbnail: convert: unable to open image `/var/www/ISWiki/prod/current/energypedia/images/8/87/Haeusleberg_farm.jpg': No such file or directory @ error/blob.c/OpenBlob/2641. convert: no images defined `/tmp/transform_551c186-1.jpg' @ error/convert.c/ConvertImageCommand/3044. A view over the Häusleberg organic farm
|
|
Error creating thumbnail: convert: unable to open image `/var/www/ISWiki/prod/current/energypedia/images/3/3a/Haeusleberg_turbine_1.jpg': No such file or directory @ error/blob.c/OpenBlob/2641. convert: no images defined `/tmp/transform_3f3537c-1.jpg' @ error/convert.c/ConvertImageCommand/3044. Side view of the installed turbine atop the wooden framed drainage barrel.
|
Error creating thumbnail: convert: unable to open image `/var/www/ISWiki/prod/current/energypedia/images/4/49/Haeusleberg_turbine_2.jpg': No such file or directory @ error/blob.c/OpenBlob/2641. convert: no images defined `/tmp/transform_1c762d3-1.jpg' @ error/convert.c/ConvertImageCommand/3044. Top view of the installed turbine atop the wooden framed drainage barrel.
|
|
|
Error creating thumbnail: convert: unable to open image `/var/www/ISWiki/prod/current/energypedia/images/a/a0/Haeusleberg_turbine_3.jpg': No such file or directory @ error/blob.c/OpenBlob/2641. convert: no images defined `/tmp/transform_4f07220-1.jpg' @ error/convert.c/ConvertImageCommand/3044. The turbine from below showing the pelton runner at the nozzle mounting bracket.
|
Error creating thumbnail: convert: unable to open image `/var/www/ISWiki/prod/current/energypedia/images/9/97/Haeusleberg_turbine_4.jpg': No such file or directory @ error/blob.c/OpenBlob/2641. convert: no images defined `/tmp/transform_481d0e3-1.jpg' @ error/convert.c/ConvertImageCommand/3044. The stator of the direct drive motor during modifications for the 12 V hybrid system.
|
|
|
Error creating thumbnail: convert: unable to open image `/var/www/ISWiki/prod/current/energypedia/images/4/41/Haeusleberg_turbine_5.jpg': No such file or directory @ error/blob.c/OpenBlob/2641. convert: no images defined `/tmp/transform_304c52e-1.jpg' @ error/convert.c/ConvertImageCommand/3044. Nozzle alignment test.
|
|
|
|
[edit] Further Information