− | ==== go to third tab <Edit> and ask your question question here ==== | + | = Overview = |
| | | |
− | <br> Answer the questions here ...
| + | To ask your question here, use '''Edit''' and type your question |
| | | |
− | <br> | + | <u>'''The following questions are already raised:'''</u> |
| | | |
− | ==== What use can a hydropower installation satisfy? ====
| + | <br/> |
| | | |
− | *Direct drive of machinery
| + | = Questions and Answers = |
− | *Electricity production for local use
| + | |
− | *Electricity feed into grid for revenue<br>
| + | |
| | | |
− | <br>
| + | ==== What demand can a hydropower installation satisfy? ==== |
| | | |
− | ==== How many people can be supplied? ====
| + | *Direct drive of machinery |
| + | *Electricity production for local use |
| + | *Electricity feed into grid for revenue |
| | | |
− | *Available <u>share per household (hh) depends on local hydro potential and type of use</u> (lighting, TV, machinery, ...)
| + | |
− | *Required power for <u>lighting</u> depends on no. and type of lamps used (3 - 5 Watt energy saving lamps are existing)<br> | + | |
− | *Machinery needs usually several kW (often machinery's power is given in HP (metrical Horsepower) 10 HP = 7.36 kW)<br>A motors starting power can be 50% higher than its regularly stated power. There are technical possibilities to address these (soft start). | + | ==== How many people can be supplied by a mhp station? ==== |
− | *Electrical heating requires very high power. E.g. has a typical water heater ~ 3 kW. Within an isolated grid, electrical heating / cooking / oven is usually not practicable. Hot water can be produced centrally from the ballast load.<br> | + | |
− | *Electrical cooling is possible. | + | Available <u>share per household (hh) depends on local hydro potential and type of use</u> (lighting, TV, machinery, ...). Calculate no. of required appliances. The consumers have to be connected towards the mhp station by a transmission line. |
| + | |
| + | Energy = power * time. Energy [Watt hours (Wh)]; Power [Watt(W)]; time [hours(h)] |
| + | *Required power for <u>lighting</u> depends on no. and type of lamps used. Fluorescence lamps require so called blind power. It may affect the system if they the only consumers. |
| + | *<u>Machinery</u> needs usually several kW (often machinery's power is given in HP (metrical Horsepower) 10 HP = 7.36 kW)<br/>A motors starting power can be 50% higher than its regularly stated power. There are technical possibilities to address these (soft start). |
| + | *<u>Electrical heating</u> requires very high power. Within an isolated grid, electrical heating / cooking / oven is usually not practicable. Hot water can be produced centrally from the ballast load. |
| + | |
| + | |
| + | |
| + | ==== What's typical Wattage of appliances? ==== |
| + | |
| + | *Water heater ~ 3-5 kW. |
| + | *Electric cooler ~ 300 W |
| + | *Freezer ~ 0.5 - 1kW |
| + | *Air condition ~ 0.7 - 1 kW |
| *Electrical fan ~ 200 Watt. | | *Electrical fan ~ 200 Watt. |
− | *Radio / DVD ~ 10 W / 2 W | + | *Radio / DVD ~ 10 W / 25 W |
− | *Water pump ~ 1 kW
| + | *TV 50 -150 W (depending on type and size |
− | *TV 50 -150 W (depending on type and size) | + | *Bulb (CFL) ~ 3 - 10 W; conventional bulbs ~ 25 - 40 W each |
| + | *Standby power for VCR / DVD / Stabilizer / satellite dish receivers / TV - ranges around 5 - 15 W each |
| + | *Electric drill ~ 300 W |
| + | *Water pump ~ 1 kW |
| | | |
− | <br> | + | <br/> |
| | | |
− | '''What are typical difficulties'''<br>
| + | ==== What are typical difficulties in setting up mhp?<br/> ==== |
| | | |
− | *financial coverage<br> | + | *<u>financial coverage</u> of installation costs have to be covered upfront |
− | *remote location<br> | + | *<u>remote location</u> requires long travels for specialists |
− | *specific conditions<br> | + | *<u>mhp equipment</u> is not available everywhere for low costs |
− | *uncertain outcome<br> | + | *<u>specific conditions</u> require special know how |
| + | *<u>uncertain outcome</u> till a pre-feasibility study is done |
| | | |
− | <br>
| |
| | | |
− | *'''Price range: '''depends on size of potential site, ranges from 2000 - 5000 USD/kW
| |
− | *'''Material needed: '''Turbine, generator, controller come from a specialist
| |
− | *'''Suitable geographic area: '''usual hilly and all year round water flow, also irrigation canals can have good hydropower potential
| |
− | *'''Required competencies: '''Experience in mhp feasibility for pre-study and planning, patience in cooperation with the local entities'''<br>'''
| |
− | *'''How Long does it take: '''Ideally flow measurements should be taken over several years to ensure safe data. A must is the measurement of the minimal flow during dry season. From there on a mhp plant can be installed within one year. Accessibility of remote location, delivery times for turbine and generator and social setup usually take longer than estimated.
| |
| | | |
− | <br>
| + | ==== Price range of mhp installations? ==== |
| | | |
− | [[Hydro|back to hydro section]]
| + | Costs depend on size of potential site. They usually range from 2000 - 5000 USD/kW |
| | | |
− | [[Category:Hydro]]
| |
| | | |
− | <br> | + | |
| + | ==== Special material required? ==== |
| + | |
| + | *Turbine, generator, controller come from a specialist producers |
| + | *Pipeline and civil works can be done by companies not necessarily specialised in mhp. Whereby experience is always an advantage. |
| + | |
| + | |
| + | |
| + | ==== Suitable areas for mhp: ==== |
| + | |
| + | *Hills and all year round water flow provide good hydropower conditions |
| + | *Waterfalls are typical indicators for mhp potential |
| + | *A river which cascades down on a short distance can be suitable for mhp |
| + | *Irrigation canals can have good hydropower potential if there is some drop in height |
| + | |
| + | |
| + | |
| + | ==== Required competence: ==== |
| + | |
| + | *mhp feasibility (pre-) study |
| + | *mhp planning |
| + | *construction supervision |
| + | *installation electromechanical equipment |
| + | *social setup |
| + | |
| + | |
| + | |
| + | ==== How Long does it take to finish a mhp installation: ==== |
| + | |
| + | Ideally flow measurements should be taken over several years to ensure safe data. A must is the measurement of the minimal flow during dry season. From there on a mhp plant can be installed <u>within one year</u>. Accessibility of remote location, delivery times for turbine and generator and social setup usually take longer than estimated. |
| + | |
| + | = <br/>Further Information = |
| + | |
| + | [[Portal:Hydro|-> back to hydro section]] |
| + | |
| + | <br/> |
| + | |
| + | = References = |
| + | |
| + | <references /> |
| + | |
| + | [[Category:Hydro]] |
Energy = power * time. Energy [Watt hours (Wh)]; Power [Watt(W)]; time [hours(h)]
Costs depend on size of potential site. They usually range from 2000 - 5000 USD/kW
Ideally flow measurements should be taken over several years to ensure safe data. A must is the measurement of the minimal flow during dry season. From there on a mhp plant can be installed within one year. Accessibility of remote location, delivery times for turbine and generator and social setup usually take longer than estimated.