(9 intermediate revisions by 3 users not shown) |
Line 1: |
Line 1: |
| | | |
| = Overview = | | = Overview = |
| + | |
| + | '''Net metering''' is a service to an electric consumer under which electric energy generated by that electric consumer from an eligible on-site generating facility and delivered to the local distribution facilities may be used to offset electric energy provided by the electric utility to the electric consumer during the applicable billing period.<ref>Wikipedia: http://en.wikipedia.org/wiki/Net_metering and http://www.ferc.gov/industries/electric/indus-act/section-1241.pdf</ref> |
| + | |
| + | <br/> |
| | | |
| = Billing<br/> = | | = Billing<br/> = |
| | | |
| <u>Organising electricity distribution requires to determine:</u> | | <u>Organising electricity distribution requires to determine:</u> |
| + | |
| *how much electricity is available | | *how much electricity is available |
| *how it is shared and limited | | *how it is shared and limited |
Line 11: |
Line 16: |
| <br/> | | <br/> |
| | | |
− | <u>Different Tariffsystems are practicable at different conditions:</u> | + | <u>Different Tariff systems are practicable at different conditions:</u> |
| + | |
| + | (see also at [[Costs and Tariff Setting - Examples|Costs and Tariff Setting - Examples]]) |
| | | |
− | (see also at [[Costs_and_Tariff_Setting|Costs and Tariff Setting]])
| |
| *Flat tariffs unlimited/limited | | *Flat tariffs unlimited/limited |
| *Item based tariffs (pay per bulb/TV/Radio) | | *Item based tariffs (pay per bulb/TV/Radio) |
Line 24: |
Line 30: |
| <u>Advantages</u> | | <u>Advantages</u> |
| | | |
− | {| cellspacing="1" cellpadding="1" border="0" align="right" style="width: 200px" class="FCK__ShowTableBorders" | + | {| style="width: 200px" class="FCK__ShowTableBorders" cellspacing="1" cellpadding="1" border="0" align="right" |
| |- | | |- |
| | | | | |
− | [[File:Digital meter.jpg|thumb|right|124px|Digital meter.jpg]] | + | [[File:Digital meter.jpg|thumb|right|124px|Digital meter]] |
| | | |
− | | [[File:Standard kWh meter.jpg|thumb|99px|Standard kWh meter.jpg]] | + | | [[File:Standard kWh meter.jpg|thumb|right|99px|Standard kWh meter]] |
| |} | | |} |
| | | |
Line 36: |
Line 42: |
| *reading can be uncoupled from tariff collection | | *reading can be uncoupled from tariff collection |
| *allows amount and time related tariffs (demand steering) | | *allows amount and time related tariffs (demand steering) |
| + | |
| + | <br/> |
| | | |
| <u>Disadvantages</u> | | <u>Disadvantages</u> |
| + | |
| *high costs (metering device) | | *high costs (metering device) |
| *especially at rural areas in dev. countries the investment cost for a meter unit are way out of range<br/> | | *especially at rural areas in dev. countries the investment cost for a meter unit are way out of range<br/> |
| *dis- and re-connection in case of late payment | | *dis- and re-connection in case of late payment |
| | | |
− | <br/><br/>
| + | <br/> |
| | | |
| = Pre-paid System with Coins or Cards = | | = Pre-paid System with Coins or Cards = |
| | | |
− | [[File:Pre-paid system.jpg|thumb|143px|Pre-paid system.jpg]] | + | [[File:Pre-paid system.jpg|thumb|right|143px|Pre-paid system]]<u>Advantages</u> |
| | | |
− | <u>Advantages</u>
| |
| *fair and transparent | | *fair and transparent |
| *no meter reading | | *no meter reading |
Line 57: |
Line 65: |
| | | |
| <u>Disadvantages</u> | | <u>Disadvantages</u> |
| + | |
| *relatively high cost for metering device | | *relatively high cost for metering device |
| *less forgery proof | | *less forgery proof |
Line 65: |
Line 74: |
| = Current Limiter / Fuses<br/> = | | = Current Limiter / Fuses<br/> = |
| | | |
− | {| cellspacing="1" cellpadding="1" border="0" align="right" style="width: 200px" class="FCK__ShowTableBorders" | + | {| style="width: 200px" class="FCK__ShowTableBorders" cellspacing="1" cellpadding="1" border="0" align="right" |
| |- | | |- |
− | | [[File:Current limiter 2.jpg|156px|fault current breaker|alt=fault current breaker]] | + | | [[File:Current limiter 2.jpg|thumb|right|156px|fault current breaker|alt=fault current breaker]] |
− | | [[File:Current limiter 1.jpg|201px|Current limiter / fuse; price may be < 5 USD|alt=Current limiter / fuse; price may be < 5 USD]] | + | | [[File:Current limiter 1.jpg|thumb|right|201px|Current limiter / fuse; price may be < 5 USD|alt=Current limiter / fuse; price may be < 5 USD]] |
| |- | | |- |
− | | [[File:100px-Electrical Fuse (aka).jpg|100px|100px-Electrical Fuse (aka).jpg|alt=100px-Electrical Fuse (aka).jpg]] | + | | [[File:100px-Electrical Fuse (aka).jpg|thumb|right|100px|100px-Electrical Fuse|alt=100px-Electrical Fuse (aka).jpg]] |
− | | [[File:180px-DIAZED fuses.jpg|180px|RTENOTITLE]] | + | | [[File:180px-DIAZED fuses.jpg|thumb|right|180px|DIAZED fuses]] |
| |} | | |} |
| | | |
| <u>Advantages</u> | | <u>Advantages</u> |
− | *simultaneously protecting against overcurrent (actual purpose | + | |
| + | *simultaneously protecting against overcurrent (actual purpose) |
| *cheap if simple versions<br/> | | *cheap if simple versions<br/> |
| *no meter reading required => indirect power flat rate according to max. amperage | | *no meter reading required => indirect power flat rate according to max. amperage |
| + | |
| + | <br/> |
| | | |
| <u>Disadvantages</u> | | <u>Disadvantages</u> |
| + | |
| *accuracy of cicuit breakers as load limiter fluctuates (even items from one batch have different trigger levels)<br/>=> neigbours with same connections may be able to use different wattage<br/> | | *accuracy of cicuit breakers as load limiter fluctuates (even items from one batch have different trigger levels)<br/>=> neigbours with same connections may be able to use different wattage<br/> |
| *fault current breaker are rarely available in < 1 Ampere range (1 A / 220 V => 220 Watt)<br/> | | *fault current breaker are rarely available in < 1 Ampere range (1 A / 220 V => 220 Watt)<br/> |
| *time of usage not considered; less fair | | *time of usage not considered; less fair |
− | *melting fuses are available and cheap but very easy to bridge (also temporarily) => encouage missuse<br/> | + | *melting fuses are available and cheap but very easy to bridge (also temporarily) => encourage misuse<br/> |
| + | |
| + | <br/> |
| + | |
| + | <br/> |
| | | |
| <br/> | | <br/> |
Line 89: |
Line 106: |
| = Flat Rate / No Metering / No Limiting<br/> = | | = Flat Rate / No Metering / No Limiting<br/> = |
| | | |
− | only in well organised small comunities a flat rate without limiting or metering will work. Consumers have to agree that everybody connected carries the same share of payment. If usage of electricity differs widely between the connected parties usually the "one tariff for all" is considered unfair.
| + | Only in well organised small communities a flat rate without limiting or metering will work. Consumers have to agree that everybody connected carries the same share of payment. If usage of electricity differs widely between the connected parties usually the "one tariff for all" is considered unfair. |
| | | |
− | Often such settings work only untill the limit of the mhp is reached and power has to be rationated. | + | Often such settings work only until the limit of the mhp is reached and power has to be rationed. |
| + | |
| + | <br/> |
| | | |
| <u>Advantages</u> | | <u>Advantages</u> |
| + | |
| *very cheap (no metering or limiting device) | | *very cheap (no metering or limiting device) |
| *in rural areas of Indonesia common and accepted as long lighting is the common/only usage<br/> | | *in rural areas of Indonesia common and accepted as long lighting is the common/only usage<br/> |
Line 99: |
Line 119: |
| | | |
| <u>Disadvantages</u> | | <u>Disadvantages</u> |
| + | |
| *provokes waste of electricity, no incentive for saving | | *provokes waste of electricity, no incentive for saving |
| *no load control / demand steering possible (peaks) | | *no load control / demand steering possible (peaks) |
Line 107: |
Line 128: |
| = Further Information = | | = Further Information = |
| | | |
− | *[[Metering_and_Billing_Battery_Charging_Systems_(BCS)|Metering and Billing Battery Charging Systems (BCS)]]<br/> | + | *[[Metering and Billing Battery Charging Systems (BCS)|Metering and Billing Battery Charging Systems (BCS)]]<br/> |
− | *[[Net_Metering|Net Metering]]<br/> | + | *[[Net Metering|Net Metering]]<br/> |
− | *[[Net_Metering_Brazil_(FRE)|Net Metering Brazil (FRE)]]<br/> | + | *[[Net Metering in Brazil|Net Metering in Brazil]]<br/> |
| + | |
| + | <br/> |
| | | |
| = References = | | = References = |
Line 115: |
Line 138: |
| <references /><br/> | | <references /><br/> |
| | | |
− | [[Category:Solar]] | + | [[Category:Net_Metering]] |
| + | [[Category:Digitalisation]] |
| + | [[Category:Net_Metering_Brazil]] |
| + | [[Category:Electricity]] |
| + | [[Category:Feed-in_Tariffs]] |
Only in well organised small communities a flat rate without limiting or metering will work. Consumers have to agree that everybody connected carries the same share of payment. If usage of electricity differs widely between the connected parties usually the "one tariff for all" is considered unfair.
Often such settings work only until the limit of the mhp is reached and power has to be rationed.