Line 1: |
Line 1: |
| {{Biogas Project Database | | {{Biogas Project Database |
− | |BSP Project Name=Thermo-technical retrofitting of public buildings | + | |BSP Project Name=Thermo-technical retrofitting of a health center |
| |BSP Project Desc=Within the project 'Energy efficiency in the grid-connected energy supply' implemented by GIZ on behalf of the German federal Ministry for Economic Cooperation and Development (BMZ) and Swiss Development Cooperation (SDC) sixteen (16) have been retrofitted. This one of these buildings. | | |BSP Project Desc=Within the project 'Energy efficiency in the grid-connected energy supply' implemented by GIZ on behalf of the German federal Ministry for Economic Cooperation and Development (BMZ) and Swiss Development Cooperation (SDC) sixteen (16) have been retrofitted. This one of these buildings. |
− | |BSP Project Status=Planned | + | |BSP Project Budget=174,100,000.00 MNT |
| + | |BSP Project Status=Completed |
| + | |BSP Project Start=01.07.2015 |
| + | |BSP Project Type=other |
| + | |BSP Project End=07.09.2015 |
| + | |BSP Project Picture=Khovd Duut.png |
| |BSP Province=46.862496, 103.846656 | | |BSP Province=46.862496, 103.846656 |
| + | |BSP Tag Building=Building improvement |
| + | |BSP Tag Efficient=Efficient use of resources |
| }} | | }} |
| + | |
| + | ==== Building data and geometry<br/> ==== |
| + | |
| + | *Construction year: 1975<br/> |
| + | *Cross volume: 3,276.8 m³<br/> |
| + | *Thermal envelope: 1,730.3 m²<br/> |
| + | *Net volume: 2,835 m³<br/> |
| + | *Net floor area: 799.3 m²<br/> |
| + | |
| + | ==== Implemented measures:<br/> ==== |
| + | |
| + | *Roof insulation with 20cm EPS- hard foam and waterproofing<br/> |
| + | *Wall insulation with 15cm EPS- hard foam<br/> |
| + | *New windows with 5-chamber plastic frame and double glazing<br/> |
| + | *New exterior doors<br/> |
| + | *Rehabilitation of the heating system<br/> |
| + | *Contracting company: Tulgat bagana LLC<br/> |
| + | |
| + | ==== Energy consumption<br/> ==== |
| + | |
| + | *Before: 522 kWh/(m2 a) {calculated}<br/> |
| + | *After: 140 kWh /(m2 a) {metred}<br/> |
| + | *Energy saving per year: 305,332 kWh<br/> |
| + | *Coal equivalent saving: 75,020 kg / 75 t<br/> |
| + | *CO<sub>2</sub> emission savings per year: 206 t CO<sub>2 </sub>{Estimated} |