| Line 33: | 
Line 33: | 
|   | === Technical Test II  ===  |   | === Technical Test II  ===  | 
|   |  |   |  | 
| − | not yet started<br>
  | + | Testkriterien Level 2  | 
|   | + |    | 
|   | + | {| cellspacing="0" cellpadding="3" width="70%" border="1"  | 
|   | + | |-  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Solarmodul</span>  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Werden die Nennwerte von Leistung, Leerlaufspannung und Kurzschlussstrom eingehalten?</span>  | 
|   | + | |-  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Batterie</span>  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Messung der Kapazität (NiMH+ Pb), Beständigkeit gegen Überladung (NiMH), einfacher Haltbarkeitstest (NiMH)</span>  | 
|   | + | |-  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Lichtstrom</span>  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Mittelwert über 210 Minuten</span>  | 
|   | + | |-  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Brennzeit/autonome Zeit</span>  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Leuchtdauer bis der Lichtstrom 70% des nach 15 min gemessenen Wertes erreicht hat (Start mit voll geladener Batterie)</span>  | 
|   | + | |-  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Lichtausbeute</span>  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Mittelwert über 210 min., Start mit voll geladener Batterie</span>  | 
|   | + | |-  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Laderegler</span>  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Spannungslevel Ladeschluss-/ Lastabwurfspannung, Eigenverbrauch, Signalisierungen, Schutz vor Entladung durch Modul, Wirkungsgrad</span>  | 
|   | + | |-  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Vorschaltgerät</span>  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Elektrischer Wirkungsgrad</span>  | 
|   | + | |-  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Zyklentest bei CFL-Leuchten</span>  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Test der Schaltfestigkeit der Leuchte mit dem Zyklus 60s an 150s aus</span>  | 
|   | + | |-  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Simulation</span>  | 
|   | + | | <span style="font-size: 11pt; font-family: arial; mso-bidi-font-size: 12.0pt; mso-fareast-font-family: 'times new roman'; mso-ansi-language: de; mso-fareast-language: de; mso-bidi-language: ar-sa">Ermittlung der solaren Deckungsrate für 5 Standorte bei einer Brenndauer von täglich 3,5 Stunden</span>  | 
|   | + | |}  | 
|   | + |    | 
|   | + | <br>  | 
|   | + |    | 
|   | + | [http://www.endev.info/index.php?option=com_docman&task=doc_download&gid=334 Technical Test II] (german)  | 
|   |  |   |  | 
|   | === Field Test  ===  |   | === Field Test  ===  | 
|   |  |   |  | 
|   | not yet started  |   | not yet started  | 
Currently engagement concerning Pico PV Systems increases. In order to advance the framework for project development in this field EnDev has effected various activities. One of these is a test series for Pico PV Systems. It is divided into three phases: 
1. Technical Test I 
2. Technical Test II 
3. Field Tests 
The technical tests are performed by Fraunhofer Gesellschaft FhG/ISE in Freiburg, Germany. In the first test phase (2007/ 10 - 2008/ 01) eleven systems were tested on road capability with special focus on mechanical stability, lighting characteristics and operability. These systems were in detail: 
|  Solarmodul
 | 
 Werden die Nennwerte von Leistung, Leerlaufspannung und Kurzschlussstrom eingehalten?
 | 
|  Batterie
 | 
 Messung der Kapazität (NiMH+ Pb), Beständigkeit gegen Überladung (NiMH), einfacher Haltbarkeitstest (NiMH)
 | 
|  Lichtstrom
 | 
 Mittelwert über 210 Minuten
 | 
|  Brennzeit/autonome Zeit
 | 
 Leuchtdauer bis der Lichtstrom 70% des nach 15 min gemessenen Wertes erreicht hat (Start mit voll geladener Batterie)
 | 
|  Lichtausbeute
 | 
 Mittelwert über 210 min., Start mit voll geladener Batterie
 | 
|  Laderegler
 | 
 Spannungslevel Ladeschluss-/ Lastabwurfspannung, Eigenverbrauch, Signalisierungen, Schutz vor Entladung durch Modul, Wirkungsgrad
 | 
|  Vorschaltgerät
 | 
 Elektrischer Wirkungsgrad
 | 
|  Zyklentest bei CFL-Leuchten
 | 
 Test der Schaltfestigkeit der Leuchte mit dem Zyklus 60s an 150s aus
 | 
|  Simulation
 | 
 Ermittlung der solaren Deckungsrate für 5 Standorte bei einer Brenndauer von täglich 3,5 Stunden
 |