− | Where a generator is used alternating current (a.c.) electricity is normally produced. Singlephase power is satisfactory on small installations up to 20kW, but beyond this, 3-phase power is used to reduce transmission losses and to be suitable for larger electric motors. An a.c. power supply must be maintained at a constant 50 or 60 cycles/second for the reliable operation of any electrical equipment using the supply. This frequency is determined by the speed of the turbine which must be very accurately governed. </meta></meta></meta></meta> | + | Where a generator is used alternating current (a.c.) electricity is normally produced. Singlephase power is satisfactory on small installations up to 20kW, but beyond this, 3-phase power is used to reduce transmission losses and to be suitable for larger electric motors. An a.c. power supply must be maintained at a constant 50 or 60 cycles/second for the reliable operation of any electrical equipment using the supply. This frequency is determined by the speed of the turbine which must be very accurately governed. </meta></meta></meta></meta> |
| + | |
| + | [[Category:Hydro]] |
| | | |
| [[Category:Hydro]] | | [[Category:Hydro]] |
Revision as of 15:46, 29 June 2009
Micro Hydropower
How it works
Hydropower is based on simple concepts. Moving water
turns a turbine, the turbine spins a generator, and electricity is produced.
Many other components may be in a system, but it all begins with the energy
already within the moving water.
Water
power is the combination of head and flow. Both must be present to produce
electricity. In a typical hydro system water
is diverted from a stream into a pipeline, where it is directed downhill and
through the turbine (flow). The vertical drop (head) creates pressure at the
bottom end of the pipeline. The pressurized water emerging from the end of the
pipe creates the force that drives the turbine. More flow or more head produces
more electricity. Electrical power output will always be slightly less than
water power input due to turbine and system inefficiencies.
Head
is water pressure, which is created by the difference in elevation between the
water intake and the turbine. Head can be expressed as vertical distance (
meters). Net head is the pressure available at the turbine when water is
flowing, which will always be less than the pressure when the water is turned
off (static head), due to the friction between the water and the pipe. Pipeline
diameter has an effect on net head.
Flow
is water quantity, and is expressed as "volume per time," such as
cubic feet per second (cfs), or liters per minute (lpm). Design flow is the
maximum flow for which your hydro system is designed. It will likely be less
than the maximum flow of your stream (especially during the rainy season), more
than your minimum flow, and a compromise between potential electrical output
and system cost.
When is hydropower micro?
The definition of micro hydropower varies in different countries and can even include systems with a capacity of a few megawatts. In some cases up to a rated capacity of 300 kW is considered as Microhydro because this is about the maximum size for most stand alone hydro systems not connected to the grid, and suitable for "run-of-the-river" installations.
But, In general Micro hydro is a
term used for hydroelectric power installations that typically produce 10 to 100 kW of power . They
are often used in water rich areas as a Remote Area Power Supply (RAPS).
Classification of Hydropower by size
Large hydro
|
More than 100 MW and usually feeding into a large
electricity grid
|
Medium-hydro
|
15 - 100 MW - usually feeding a grid
|
Small-hydro
|
1 - 15 MW - usually feeding into a grid
|
Mini-hydro
|
Above 100 kW, but below 1 MW; either stand alone
schemes or more often feeding into the grid
|
Micro-hydro
|
From 5kW up to 100 kW; usually provided power for a small community or rural industry in remote areas away from the grid.
|
Pico-hydro
|
From a few hundred watts up to 5kW
|
|
|
Micro
hydro is perhaps the most mature of the modern small-scale decentralized energy
supply technologies used in developing countries. There are thought to be tens of thousands of
plant in the “micro” range operating successfully in China[1], and significant numbers are operated in wide ranging countries such as
Nepal,
Sri Lanka,
Pakistan,
Vietnam
and Peru. This experience shows that in certain
circumstances micro hydro can be profitable in financial terms, while at
others, even unprofitable plant can exhibit such strong positive impacts on the
lives of poor people.
Components of a Micro Hydro system
[[Image:|Image:Micropowerplante02.jpg]][[Image:]]
Suitable conditions for micro-hydro power
The best geographical areas for
exploiting small-scale hydro power are those where there are steep rivers
flowing all year round, for example, the hill areas of countries with high
year-round rainfall, or the great mountain ranges and their foothills, like the
Andes and the Himalayas. Islands with moist marine climates, such as the
Caribbean Islands, the Philippines and Indonesia are also suitable. Low-head
turbines have been developed for small-scale exploitation of rivers where there
is a small head but sufficient flow to provide adequate power.
To assess the suitability of a potential site, the hydrology of the site
needs to be known and a site survey carried out, to determine actual flow and
head data. Hydrological information can be obtained from the meteorology or
irrigation department usually run by the national government. This data gives a
good overall picture of annual rain patterns and likely fluctuations in
precipitation and, therefore, flow patterns. The site survey gives more
detailed information of the site conditions to allow power calculation to be
done and design work to begin. Flow data should be gathered over a period of at
least one full year where possible, so as to ascertain the fluctuation in river
flow over the various seasons. There are many methods for carrying out flow and
head measurements and these can be found in the relevant texts.
<span />
Measuring Head & Flow
[[Image:|Stream Illustration]]
Before
designing a hydro system or estimating how much electricity it will
produce, four essential measurements
should be taken:
•
Head (the vertical distance between the intake and turbine)
• Flow (how much water comes down the stream)
• Pipeline (penstock) length
• Electrical transmission line length (from turbine to home or battery bank)
Head
and flow are the two most important facts of a hydro site. This will determine everything about the hydro
system—pipeline size, turbine type, rotational speed, and generator size. Even
rough cost estimates will be impossible until head and flow are measured. Accuracy is
important when measuring head and flow. Inaccurate
measurements can result in a hydro system designed to the wrong specifications,
and one that produces less electricity at a greater expense.
Calculation o Hydro Power
Power
is measured in watts or Kilowatts.
I
kW = 1000W
Flow:
1 m³/s = 1000 l/s
Gross
head = Head of the water
Net
head : Deducted the energy loss from forebay through penstock to hydro turbine,
a little smaller than gross head.
The
hydro power in a stream or a river can be calculated as follows:
Hydro
power ( kW ) = Net head ( m ) x Flow ( m³/s ) x Gravity ( 9.81 m/s² )*
(
9.81 is acceleration due to gravity which can be assumed to be constant )
For
example, If the available flow is 0.15 cubic meters per second and the net head
is 4.7 metres, the hydro power is= 4.7 x 0.15 x 9.81 = 6.9 kW
If
the flow in litres per second ( l/s ) is used, then the power will be given in
watts instead of kilowatts.
To
estimate the electrical power produced by a generator, the efficiency of the
system must be taken into consideration. Efficiency is the word used to
describe how well the power is converted from one form to another. A turbine that has an efficiency of
70 % will convert 70 % of the hydraulic power into mechanical power ( 30% being
lost ). The system efficiency is the combined efficiency of all the processes
together. The system efficiency for electricity generation using micro hydro is
typically between 50% and 60%.
Electrical
power = Hydro power X System efficiency
I.e.
as a rough estimate, if there is found to be 6.9 kW of hydro power in a small
river, the electrical power is = 6.9 x 50% = 6.9 x 0.5 = 3.45 kW
(the theoretical power must be multiplied by 0.50 for a more realistic
figure).
If a machine is operated under conditions other than
full-load or full-flow then other significant inefficiencies must be
considered. Part flow and part load characteristics of the equipment needs to
be known to assess the performance under these conditions. It is always
preferable to run all equipment at the rated design flow and load conditions,
but it is not always practical or possible where river flow fluctuates
throughout the year or where daily load patterns vary considerably.
Depending
on the end use requirements of the generated power, the output from the turbine
shaft can be used directly as mechanical power or the turbine can be connected
to an electrical generator to produce electricity. For many rural industrial
applications shaft power is suitable (for food processing such as milling or
oil extraction, sawmill, carpentry workshop, small scale mining equipment,
etc.), but many applications require conversion to electrical power. For domestic
applications electricity is preferred. This can be provided either:
•
directly to the home via a small electrical distribution system or,
• can be supplied by means of batteries which
are returned periodically to the power house for recharging - this system is
common where the cost of direct electrification is prohibitive due to scattered
housing (and hence an expensive distribution system),
Where a generator is used alternating current (a.c.) electricity is normally produced. Singlephase power is satisfactory on small installations up to 20kW, but beyond this, 3-phase power is used to reduce transmission losses and to be suitable for larger electric motors. An a.c. power supply must be maintained at a constant 50 or 60 cycles/second for the reliable operation of any electrical equipment using the supply. This frequency is determined by the speed of the turbine which must be very accurately governed. </meta></meta></meta></meta>